Opened 12 years ago

Closed 12 years ago

#612 closed defect (fixed)

Confusion in "6.4.5 Up-right diagonal scanning array initialization process"

Reported by: jeunder Owned by: bbross
Priority: minor Milestone:
Component: Text Version: D7 (I1003) d7
Keywords: Cc: bbross, wjhan, jct-vc@…

Description

In 6.4.5, the following two statements make me confuse,

"If blkWidth is less than 8 and blkHeight is less than 8"

and

"Otherwise (blkWidth is greater than 4 or blkHeight is greater than 4)"

Maybe "less than 8" change to "less than or equal to 4" is better ?

Change History (2)

comment:1 Changed 12 years ago by DefaultCC Plugin

  • Cc bbross wjhan jct-vc@… added

comment:2 Changed 12 years ago by bbross

  • Resolution set to fixed
  • Status changed from new to closed

Fixed in JCTVC-I1003_d8.