Opened 13 years ago Closed 13 years ago #301 closed defect (fixed)Missing description about pcm_sample_loop_filter_disable_flag for SAO
Description
The current WD text misses the description about the combination of SAO and pcm_sample_loop_filter_disable_flag. Attachments (1)Change History (3)comment:1 Changed 13 years ago by DefaultCC Plugin
Changed 13 years ago by kchonocomment:2 Changed 13 years ago by wjhan
Rather than attached solution, WD can be changed as follows:
8.6.2 Sample adaptive offset process
[before]
When aps_sample_adaptive_offset_flag is equal to 1, the following applies:
[after]
When aps_sample_adaptive_offset_flag is equal to 1 and pcm_loop_filter_disable_flag is equal to 0, the following applies:
Semantics of pcm_loop_filter_disable_flag should be modified also, and the inference when the syntax item is not present should be added since this syntax is conditionally present depends on pcm_enabled_flag. Note: See
TracTickets for help on using
tickets. | This list contains all users that will be notified about changes made to this ticket. These roles will be notified: Reporter, Owner, Subscriber, Participant
|
Revised version of 8.6.2.1.1 Modification process for luma and chroma samples