Opened 13 years ago Closed 13 years ago #233 closed defect (fixed)[WD4] Issue in specification of Intra_Angular prediction mode
Description
The current WD4 does not describe the intra angular prediction properly for IntraPredOrder greater than or equal to 18. In that case, the predictor obtained is a transposition of the expected result.
Find attached a proposed revision of the Intra_Angular prediction mode specification (starting after the invAngle table). Attachments (2)Change History (7)Changed 13 years ago by tkunlincomment:1 Changed 13 years ago by bbross
comment:2 Changed 13 years ago by davidf
comment:3 Changed 13 years ago by bbross
comment:4 Changed 13 years ago by wjhancomment:5 Changed 13 years ago by bbross
Fixed in D6 (H1003) dI Note: See
TracTickets for help on using
tickets. | This list contains all users that will be notified about changes made to this ticket. These roles will be notified: Reporter, Owner, Subscriber, Participant
|
Confirmed. And due to adoption of H0407 (logical mode numbering), "less than 18" should replaced by "equal or greater than 18" additionally.
Attached file is the fix based on D6 dG. According to the software behavior, I added "swapped process for horizontal-like directions" on top of current text.