check syntax elements to match profile and level requirements

Reported by: PhuongNguyen Owned by:
Priority: minor Milestone: HM-13.0
Component: HM Version: HM-11.0
Keywords: Cc: fbossen, ksuehring, davidf, jct-vc@…

Description

The spec requires limits for syntax elements in a given profile or level. For instance, for level 5 and higher levels, the value of CtbSizeY must be equal to 32 or 64.

It will be very helpful to add the checks of these limits in the reference decoder to detect the stream does not violate spec requirements.

Best regards,
Phuong.

Change History (3)

comment:1 Changed 11 years ago by DefaultCC Plugin

  • Cc fbossen ksuehring davidf jct-vc@… added

comment:2 Changed 11 years ago by ksuehring

Patches for adding such functionality are always welcome.

comment:3 Changed 11 years ago by fbossen

  • Milestone set to HM-13.0
  • Resolution set to fixed
  • Status changed from new to closed

Added check in r3782