Opened 10 years ago

Closed 10 years ago

#71 closed mismatch (fixed)

IC parameters is meaningless in HTM when no training samples are available

Reported by: HongbinLiu Owned by: tech
Priority: minor Component: HTM software
Version: Keywords:
Cc: tech, jct-3v@…

Description

In 3D-HEVC text, when no training samples are available for training IC parameters, IC is not performed, this is reasonable.
However, in HTM, meaningless IC parameters are used in this case.

Should align HTM with 3D-HEVC text.

Attachments (1)

ticket#71.zip (28.3 KB) - added by HongbinLiu 10 years ago.
patch for fixing the problem

Download all attachments as: .zip

Change history (3)

comment:1 Changed 10 years ago by DefaultCC Plugin

  • Cc tech jct-3v@… added

Changed 10 years ago by HongbinLiu

patch for fixing the problem

comment:2 Changed 10 years ago by tech

  • Resolution set to fixed
  • Status changed from new to closed

The bug is fixed in branches/HTM-11.2-dev0 Rev. 1036. The fix will be part of a future HM release.

Note: See TracTickets for help on using tickets.

This list contains all users that will be notified about changes made to this ticket.

These roles will be notified: Reporter, Owner, Subscriber, Participant

  • Gerhard Tech(Owner, Subscriber, Participant, Always)
  • Hongbin Liu(Reporter)
  • jct-3v@…(Subscriber)
  • Karsten Suehring(Always)