Opened 12 years ago Closed 12 years ago #936 closed defect (fixed)description of hrd_op_set_idx has conflicting information
Description
The WD contains the following in the description of hrd_op_set_idx[i]
The first sentence says the value "shall be equal to 0." The second sentence says "is required to be less than or equal to 1 ..." The second sentence adds conflicting information by allowing for a value of 1 that is prohibited by the first sentence. It is suggested that the second sentence be shortened to "Decoders shall allow other values ..." Change History (2)comment:1 Changed 12 years ago by DefaultCC Plugin
comment:2 Changed 12 years ago by bbross
Note: See
TracTickets for help on using
tickets. | This list contains all users that will be notified about changes made to this ticket. These roles will be notified: Reporter, Owner, Subscriber, Participant
|
Fixed in JCTVC-L0030.