Opened 13 years ago Closed 10 years ago #185 closed defect (invalid)Improper TU size for NxN PU when max RQT depth = 1
Description
We discovered a bug in HM-3.1 implementation of implicit RQT split for max depth=1 and PU split. Specifically, 2Nx2N TU for NxN PU in inter CU is chosen when NxN TU should be used. Change History (5)comment:1 Changed 13 years ago by davidf
comment:2 Changed 13 years ago by davidf
comment:3 Changed 13 years ago by davidf
comment:4 Changed 12 years ago by ksuehring
comment:5 Changed 10 years ago by ksuehring
(Based on current text) As far we understand the report, this behavior is allowed and thus no bug. Note: See
TracTickets for help on using
tickets. | This list contains all users that will be notified about changes made to this ticket. These roles will be notified: Reporter, Owner, Subscriber, Participant
|
Updating component after adding WD (Text) tickets