Opened 10 years ago Last modified 6 years ago #1384 closed enhancementorphaned symbol in the spec — at Initial Version
Description
The paragraph just before E.3.2 section says:
log2_max_mv_length_horizontal and log2_max_mv_length_vertical indicate the maximum absolute value of a decoded horizontal and vertical motion vector component, respectively, in quarter luma sample units, for all pictures in the CVS. A value of n asserts that no value of a motion vector component is outside the range of −2n to 2n − 1, inclusive, in units of quarter luma sample displacement. The value of log2_max_mv_length_horizontal shall be in the range of 0 to 16, inclusive. The value of log2_max_mv_length_vertical shall be in the range of 0 to 15, inclusive. When log2_max_mv_length_horizontal is not present, the values of log2_max_mv_length_horizontal and log2_max_mv_length_vertical is inferred to be equal to 15.
What "n" here stands for? Note: See
TracTickets for help on using
tickets. | This list contains all users that will be notified about changes made to this ticket. These roles will be notified: Reporter, Owner, Subscriber, Participant
|