Opened 11 years ago

Closed 11 years ago

#1244 closed defect (fixed)

Derivation of POC when CRA has NoRaslOutputFlag equal to 1

Reported by: hendry Owned by:
Priority: minor Milestone: HM-14.0
Component: HM Version: HM-13.0
Keywords: Cc: fbossen, ksuehring, davidf, jct-vc@…

Description

When CRA follows an EOS, the variable NoRaslOutputFlag is set to 1 and POC MSB for that CRA shall be set to 0.

Currently, this is not implemented yet.

Attachments (1)

FixCRAPocWhenNoRaslOutputFlagIsTrue.patch (1.1 KB) - added by hendry 11 years ago.
Patch that may address the reported issue

Download all attachments as: .zip

Change History (3)

comment:1 Changed 11 years ago by DefaultCC Plugin

  • Cc fbossen ksuehring davidf jct-vc@… added

Changed 11 years ago by hendry

Patch that may address the reported issue

comment:2 Changed 11 years ago by fbossen

  • Resolution set to fixed
  • Status changed from new to closed

Fixed in r3856

Note: See TracTickets for help on using tickets.

This list contains all users that will be notified about changes made to this ticket.

These roles will be notified: Reporter, Owner, Subscriber, Participant

  • David Flynn(Subscriber)
  • Frank Bossen(Subscriber, Participant)
  • Hendry(Reporter)
  • jct-vc@…(Subscriber)
  • karl.sharman@…(Always)
  • Karsten Suehring(Subscriber, Always)