#1465 fixed Wrong payload type for alternative_transfer_characteristics SEI message matteon
Description

The current payloadType for this SEI message is still equal to the old ICD (182) in SEI.h;

ALTERNATIVE_TRANSFER_CHARACTERISTICS = 182,

This should be now amended to 147 as indicated in V3 of the spec.

#1462 worksforme Cygwin Install mbernardo
Description

Can anyone explain how to run the makefile inside the build/linux on cygwin, without errors?

#1460 fixed MV search range in HM-16.13 Tomohiro Ikai
Description

At the Chengdu meeting, it was agreed to use 256 MV search range for RA, but it seems the latest HM(HM16.13)'s cfg(encoder_randomaccess_main.cfg and encoder_randomaccess_main10.cfg) remains to use 64.

SearchRange : 64 # (0: Search range is a Full frame)

In the meeting note (JCTVC-Y_Notes_d3.doc): JCTVC-Y0052 BoG ... The increased motion search range was especially suggested for high resolutions like class A and random access. Further discussed Thu 1620 (GJS): Decision (CTC SW): Use 256 for RA only (all picture resolutions).