﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
697	Typo in 8.5.2.1.2 about setting availableFlagN	tajime	bbross	"There are duplicate conditions for setting availableFlagN as below.

-N is equal to B2 and the prediction units covering luma location (xA1, yA1) and luma location (xN, yN) have the same motion vectors and the same reference indices
-N is equal to B2 and the prediction units covering luma location (xA1, yA1) and luma location (xN, yN) have the same motion vectors and the same reference indices

One condition should be changed to:

-N is equal to B2 and the prediction units covering luma location (xB1, yB1) and luma location (xN, yN) have the same motion vectors and the same reference indices
"	defect	closed	trivial	D8	Text	D8 (J1003) d7	fixed		bbross wjhan jct-vc@…